Industry Type
Cement
Product Group
Lotherme
Product
Lotherme 510N
Problem
Crack
Dimensions (mm)
1200×40
Product
Lotherme 352
Job Picture Before Repair
Job Picture After Repair
Wear Factor
Dynamic Loads
Temp (Deg. C)
150
Material Handled
Cement
Base Metal
SA 516 Gr 70
Equipment Name
Cement Mill Shell
1. D P test on original crack
2. Drillingof 8 mm holes at the ends of the crack.
3. V grove preparation by gouging with lotherme 802 and grinding.
4. Pre-heated the job upto 150° cen
5. Roote layer started with loth 352, 3.15 mm
6. After root run grinding, d p test,
7. Againe pre-heated the job upto 150° cen
8. Multy layers started with lotherme 352, 4.00 mm and final 2 layer with lotherme 510 n
9. In side back gouging by grinding & dp test,
10. Inside welding with lotherme 352, and lotherme 510 n