HOME >Case Studies> STEEL INDUSTRY

Hard Facing of Blow Bars

Industry Type
Steel

Product Group
Lotherme

OUR SOLUTION

Polarity
Straight

Power Source
Rectifier

Quantity (Kgs)
8.00, 1.50

Current (amps)
130-160, 120-160

Size (mm)
4.00

Product
Lotherme -607, Lotherme -604

JOB PICTURES
Job Sketch With Dimension

Job Sketch With Dimension

Job Sketch With Dimension

Job Sketch With Dimension

ANALYSIS

Dimensions (mm)
665 x 50 x 200

Comp. Weight(K.G.)
57

Base Metal
Mn Steel

Problem Due To
Impact & Abrasion

Type Of Problem
Worn Out

Component Name
Blow Bars

Equipment Name
Coal Handling Plant

1. Clean the welding area.

2. Put the Blow Bars in water Tub (as shown)

3. Welding is carried out as per skip welding technique to maintain the inter pass temperature.Lotherme-607 is used as buffer layer &2-3 layers of Lotherme-604 are used for final layers.

4. Use stringer bid technique to avoid excess heat in- put.