Ductile Iron Pipe Joining For Pressur Test

Industry Type

Steel

Product Group

Mech

OUR SOLUTION
Product

Lotherme-703, Lotherme-705

Size (mm)

3.15

Current (amps)

100, 105

Quantity (Kgs)

14, 12

Process

Rectifier

Polarity

Straight

Preheat (°C)

60

JOB PICTURES
Ductile Iron Pipe Joining With Lotherme 703,705.
Hydralic Pressur Test Found Ok
ANALYSIS
Equipment Name

Pipe

Component Name

Pipes

Type Of Problem

Broken

Problem Due To

Joining For Pressur Testing

Previous Solution

XYRON 2240

Base Metal

Ductile Iron

Dimensions (mm)

6000 x 10 x 200

Procedure

1. 4 Pipes edges made the grove by grinding machine.

2. Each pipe joints made tocka weld apposit sides

3. Pre heated the pipes up to 60 dig.

4. Cast iron welding prociser made the grove joinings 50mm opposite sides and complited the total pipe welding using our lotherme 705 dia 3.15mm and one more pipe with lotherme 703 dia 3.15mm.

5. They tested the both the pipes hydralic pressur test found satisfactory.

Further Reading on Case Studies

STEEL INDUSTRY

Pipe

Ductile Iron Pipe Joining For Pressur Test

Read Case Study
Choose Any Option To Contact Us
×

Contact Us